Labels:text | screenshot | font | document | black and white | number | parallel OCR: DIAGNOSIS OF THE ELECTRONIC DIGITAL INSTRUMENT CLUSTER PROBLEM POSSIBLE CAUSE CORRECTION Cluster Display Does Not Light 1. No ignition feed to the cluster. 1. Remove the large 17 pin connector from the cluster. Using a digital volt- OHM meter, measure the voltage from pin A13 to ground with the ignition in run. The meter should read battery voltage. If the meter reads less than battery voltage, or zero, repair the pink/white wire from the ignition 2. No ground to the cluster. 2. Measure the resistance from pin A15 switch. and A16 to ground using a digital volt- OHM meter. If the meter reads any- thing but 0 - 0.5 OHMs, repair the 3. Inoperative cluster black wires at A15 and A16 to ground. 3. Replace the cluster. Cluster Display Does 1. Park lamp feed open or shorted. Not Dim With Lights 1. Measure between pin A8 of the large 17 pin connector, and ground using a On digital volt.OHM meter. Ignition in run, parking lamps on.If the reading is less than battery voltage, repair the open or 2. Park lamp switch feed open or short- short at the brown wire. 2. Measure between pin A8 of the large ed 17 pin connector, and ground using a digital volt-OHM meter. Ignition in run, parking lamps on.Adjust the panel lamp switch from high intensity to low intensity. The vollmeter should read between 0 to battery voltage. If this reading is not obtained, repair the gray 3. Cluster inoperative. wire and/or the park lamp switch. 3. If the previous 2 steps are OK, replace the instrument cluster. Cluster Display Inoperative cluster. Replace the cluster. Always Dim Cluster Display Does Not Switch Between 1. Inoperative cluster control switch or 1. Disconnect the large 17 pin connector English and Metric wiring at the cluster, Measure the resistance between pin A2 and ground. The resis- tance should be zero in one position, and open in the other. If the switch does not respond in this manner. repair the light blue wire from the clus- ter to the switch, the switch, or the 2. Inoperative cluster. black wire from the switch to ground. 2. If the switch and wiring are correct, replace the cluster. Speedometer Inoper- Inoperative instrument cluster. Replace the cluster. ative or Inaccurate. Odometer Operates Correctly One Or Both Odom- Inoperative instrument cluster. Replace the cluster. eters Do Not Oper- ate Proberly But The Speedometer Oper- ates Properly